What Is the Upper Range Limit on a Moving Range Chart?

The upper range limit is the line on a moving range (mR) chart at 3.268 times the average moving range. A moving range above it means the jump between two consecutive values was unusually large, which points to a sudden change worth investigating.

Key facts

  • Upper range limit = 3.268 × average moving range.
  • The mR chart has no lower limit: a small change is never a signal.
  • A large moving range often accompanies a point outside the natural process limits.

How it helps

The X chart can miss a sudden drop from a high value to a low one that both sit inside the limits. The mR chart catches the size of the jump itself. Read the two together: a spike in the moving range tells you when the change happened.

Updated 2026-11-08. Method: Shewhart's control chart as taught by Donald Wheeler in Understanding Variation.