Why Is 2.66 Used in XmR Chart Limits?
2.66 is 3 divided by 1.128. The constant 1.128 (called d2) converts an average moving range of two consecutive values into an estimate of the standard deviation of routine variation, so average ± 2.66 × average moving range gives three-sigma natural process limits.
Key facts
- 2.66 = 3 ÷ 1.128 (d2 for subgroups of two).
- Sigma estimate = average moving range ÷ 1.128.
- 3.268 (D4 for subgroups of two) gives the upper range limit on the mR chart.
- With the median moving range, the factors are 3.14 for the limits and 3.865 for the upper range limit.
Why three sigma?
Shewhart chose three-sigma limits as an economic balance: wide enough that routine variation rarely crosses them, narrow enough that real changes usually do. They work well across the skewed and irregular shapes business data takes, without assuming a normal distribution.
Frequently asked questions
Can I use 3 × the standard deviation instead?
Not with the global standard deviation: it is inflated by any shifts in the data and makes the limits too wide. Using the moving ranges is what keeps the chart sensitive.
Updated 2026-11-08. Method: Shewhart's control chart as taught by Donald Wheeler in Understanding Variation.